搜索资源列表
modbuscom6
- 自己写的用于modbusrtu的通讯,可以连接各类变频器温控仪等,而且是完整的工程文件,可以修改做他用-himself wrote for modbusrtu communications, can be connected to various types of converter temperature control instrument, but it is a complete engineering documents can be amended so he
bianpinqi
- 串口通讯是工控行业最常用通讯方式之一,变频器的广泛应用更使这种通讯得以迅速发展-Industrial Serial communication is the most commonly used communications industry one way, Inverter more extensive application of this rapid development of communication
G11Test
- 一个用于测试富士G11/P11变频器通讯的小工具,在调试富士变频器RS485通讯时很有帮助。它可以读写转速以及频率,还有对输入输出的字符进行记录。 -a test for Fuji G11/P11 small inverter communication tools, Fujitsu Inverter debugging RS485 communication helpful. It can read and write speed and frequency, and the input
PLC
- PLC源程序三菱FX系列PLC与三菱变频器通讯应用实例
EasySerialPort
- 可用于无协议串口调试和标准Modbus调试。例案:单片机无协议通信、变频器通信调试、PLC及工业仪表通信调试。
modbusRTU
- 西门子PLC200与台达变频器通信程序示例,VB与VB.net两个版本
TestDELTA.rar
- 用于测试台达变频器RS485通讯的一个测试工程,详细介绍了基本的参数设置,通讯方法。,for testing in Taiwan RS485 converter of a communications test works, detailing the basic parameter setting, communication methods.
Transducer.rar
- 台达变频器通讯软件:台达变频器使用RS-485通讯,计算机与其通讯时,只要在计算机端加一个“RS-232转RS-485”就可以了。本软件在工业现场使用多年。,Tatsu Units Inverters communication software: Tatsu Inverter Units using RS-485 communications, computer and its communication, as long as the client on the computer plus
VB_Modbus-RTU
- VB6.0与变频器的RS485或Modbus通讯,控制变频器的参数设定,运行状态,运行频率,读当前状态,电流,电压,频率,故障等。支持远距离控制。-VB6.0 and drive the RS485 or Modbus communications, control the inverter parameter settings, operation status, operating frequency, read the current state, current, voltage, fr
Inverter2
- 本程序是我部开发的变频器CAShitc V1.0对应的上位机控制程序,通信采用的是Modbus协议,本人测试没有问题。请大家指教-This procedure was developed by the Department of inverter I CAShitc V1.0 PC corresponding control procedures, communications using the Modbus protocol, I test no problem. Please advice
Crc
- VB CRC编程2000变频器通讯程序带闭环-VB CRC program in 2000 inverter with closed-loop communication process
flext2
- 单片机MCS80C-196KB与台达变频器的通讯程序,本人已经在生产中用过,效果不错,大家可以使用-Singlechip MCS80C-196KB Delta inverter with the communication process, I have been used in production, good results, we can use
VB
- 可实现上位机对1~255台变频器的启停,参数监视等功能,非常实用。-PC can be 255 to 1 to start and stop inverters, parameter monitoring and other functions, very useful.
FD_V_Control
- 利用Serial Port类通过485接口实现对艾默生TD1000变频器的启动 停机 频率设定-Serial Port class through the use of 485 interface to the Emerson TD1000 start-stop frequency converter to set
zi
- 在本系统中,信息序列在先经过FSK调制,经过截止频率为25kHz的低通滤波器后(把信号频率限制在25kHz),再进入混频器搬移到更高的频率发送出去,在接收端,用与发送端同步的跳频信号对其进行变频(跳频的解跳处理在此进行),取下边频,然后进行FSK的解调-In this system, the message sequence prior through FSK modulation, through the cut-off frequency of 25kHz after low-pass fi
VB-MicroMaster440
- 完整的VB与西门子MicroMaster440变频器通讯的上位机程序源码.-Complete VB and Siemens MicroMaster440 inverter PC communication program source code.
XF-S801
- 串行口RS485自定义通讯协议,2、功能定义 (1) 监视从机运行状态 (2) 控制从机运行 (3) 读取从机功能码参数 (4) 设置从机功能码参数 3、通信协议方式 PC,PLC 为主机,变频器为从机。采用主机“轮询” , 从机“应答”的点对点的通信方式。轮询可以建立在一个轮询表内,如果是广播发送变频器不用应答。用户可以利用变频器键盘设置变频器的本机地址(默认为00H)。--Custom RS485 serial port communication protocols, 2, functio
tdCRC
- 台达变频器通信操作.若有问题就提出!速度更新-Delta converter
FC485_Test
- 丹佛斯变频器通过RS485端口通讯的例子-RS485 Comm
Modbus_soft
- 实现电脑与 Delta V FD-M 变频器通讯,特意用 VB6.0 编了一个 Modbus 协议通讯软件。 Modbus 的 ASCII 协议和RTU 协议都已经实现。 现在将源程序上传-Computer with Delta V FD-M inverter communication, a Modbus protocol communications software specially compiled with VB6.0. Modbus ASCII protocols